logo
ホーム 製品他のセンサー

APM3000 Infrared Dust Particle Sensor PM2.5 Sensor Detection Module

認証
中国 ShenzhenYijiajie Electronic Co., Ltd. 認証
中国 ShenzhenYijiajie Electronic Co., Ltd. 認証
オンラインです

APM3000 Infrared Dust Particle Sensor PM2.5 Sensor Detection Module

APM3000 Infrared Dust Particle Sensor PM2.5 Sensor Detection Module
APM3000 Infrared Dust Particle Sensor PM2.5 Sensor Detection Module

大画像 :  APM3000 Infrared Dust Particle Sensor PM2.5 Sensor Detection Module

商品の詳細:
起源の場所: CN
モデル番号: APM3000
お支払配送条件:
最小注文数量: 1
価格: 交渉可能
パッケージの詳細: 紙の箱
受渡し時間: 3-5作業日
支払条件: L/C、D/A、D/P、T/T、Western Union、MoneyGram
供給の能力: 5000pcs

APM3000 Infrared Dust Particle Sensor PM2.5 Sensor Detection Module

説明
電源電圧: 4.8-5.2V DC 動作電流: 通常、10MA、最大12MA
スタンバイ電流: 通常、2MA、最大3MA 測定可能な粒子径: 1-10μm
粒子濃度範囲: 0〜1000μg/m3 応答時間: 8秒
ハイライト:

infrared dust particle sensor

,

PM2.5 sensor module

,

dust detection sensor with warranty

 

                           APM3000 Infrared Dust Particle Sensor PM2.5 Sensor Detection Module

 

 

1. Applications

  • Indoor Air Quality Monitoring Devices: Integrated into standalone PM2.5 monitors for homes, offices, or schools to real-time display indoor PM2.5 concentrations, helping users grasp air quality changes (e.g., from cooking fumes or outdoor smog infiltration).
  • Air Purifiers & HVAC Systems: Used as a core detection component in air purifiers or heating, ventilation, and air conditioning (HVAC) systems—enabling automatic adjustment of fan speed or purification intensity based on real-time PM2.5 levels, optimizing energy efficiency and purification effects.
  • IoT & Smart Home Ecosystems: Compatible with IoT hardware (e.g., smart thermostats, smart sockets with air quality functions) to transmit PM2.5 data to cloud platforms or mobile apps, supporting remote monitoring and intelligent scene linkage (e.g., triggering air purifiers when PM2.5 exceeds a threshold).
  • Automotive Air Quality Systems: Applied in in-vehicle air quality monitors or built-in car air purifiers to detect PM2.5 from road dust or exhaust, ensuring healthy air for passengers during commutes.
  • Industrial & Commercial Environments: Used in light industrial workshops (e.g., electronics assembly plants) or commercial spaces (e.g., shopping malls, hospitals) to monitor particulate pollution, meeting basic air quality management requirements.

2. Features

  • Accurate PM2.5 Target Detection: Specialized in measuring PM2.5 (particles with diameter ≤2.5μm) with a typical accuracy of ±15% of reading (0–1000μg/m³), ensuring reliable data for air quality assessment.
  • Fast Response & Real-Time Data: Boasts a short response time (≈8s) and 1-second data refresh frequency, enabling quick capture of sudden PM2.5 concentration changes (e.g., from temporary dust sources).
  • Low Power Consumption: Operates at a typical current of 10mA (max 12mA) and standby current of 2mA (max 3mA), suitable for battery-powered devices (e.g., portable monitors) or long-term continuous operation.
  • Wide Environmental Adaptability: Functions stably in a temperature range of -20°C to 75°C and 0–95% RH (non-condensing), adapting to harsh indoor/outdoor (protected) environments without performance loss.
  • Compact & Easy Integration: Features a small form factor (approx. 46.3×34.2×19mm) and digital output (PWM signal), simplifying circuit design and installation into various devices with limited space.
  • Long Service Life: Offers an expected lifespan of around 5 years under normal operation, reducing the need for frequent sensor replacement and lowering maintenance costs for end products.

 

 

Parameter

Specification

Test Conditions

Sensor Type Infrared Dust Particle Sensor (PM2.5 Focus) -
Manufacturer ASAIR -
Detection Principle Infrared Scattering -
Measurable Particle Size ≥1μm (focus on PM2.5) -
Measurement Range (PM2.5) 0 - 1000 μg/m³ -
Measurement Accuracy ±15% of reading

0 - 100 μg/m³

100 - 1000 μg/m³

Data Refresh Rate 1 second -
Response Time ≤8 seconds T90
Power Supply Voltage 4.8 - 5.2 V DC -
Operating Current

Typical: 10 mA

Maximum: 12 mA

During measurement
Standby Current

Typical: 2 mA

Maximum: 3 mA

Idle mode
Warm-up Time ≤60 seconds After power-on
Output Signal PWM (Pulse Width Modulation) Digital output
Operating Temperature Range -20°C to 75°C -
Operating Humidity Range 0 - 95% RH Non-condensing
Storage Temperature Range -40°C to 85°C -
Storage Humidity Range 0 - 99% RH -
Dimensions 46.3 × 34.2 × 19 mm Approximate
Weight Approximately 25 g -
Expected Lifespan 5 years Under normal operating conditions

 

 

APM3000 Infrared Dust Particle Sensor PM2.5 Sensor Detection Module 0

 

連絡先の詳細
ShenzhenYijiajie Electronic Co., Ltd.

コンタクトパーソン: Miss. Xu

電話番号: 86+13352990255

私達に直接お問い合わせを送信 (0 / 3000)