logo
ホーム 製品ガス センサー

HCN-A1 Electrochemical Hydrogen Cyanide (HCN) Gas Sensor Widely For Toxic HCN Detection In Industrial Safety Scenarios

認証
中国 ShenzhenYijiajie Electronic Co., Ltd. 認証
中国 ShenzhenYijiajie Electronic Co., Ltd. 認証
オンラインです

HCN-A1 Electrochemical Hydrogen Cyanide (HCN) Gas Sensor Widely For Toxic HCN Detection In Industrial Safety Scenarios

HCN-A1 Electrochemical Hydrogen Cyanide (HCN) Gas Sensor Widely For Toxic HCN Detection In Industrial Safety Scenarios
HCN-A1 Electrochemical Hydrogen Cyanide (HCN) Gas Sensor Widely For Toxic HCN Detection In Industrial Safety Scenarios

大画像 :  HCN-A1 Electrochemical Hydrogen Cyanide (HCN) Gas Sensor Widely For Toxic HCN Detection In Industrial Safety Scenarios

商品の詳細:
起源の場所: 英国
モデル番号: hcn-a1
お支払配送条件:
最小注文数量: 1
価格: 交渉可能
パッケージの詳細: 紙箱
受渡し時間: 3-5作業日
支払条件: L/C、D/A、D/P、T/T、ウェスタンユニオン、マネーグラム
供給の能力: 5000個

HCN-A1 Electrochemical Hydrogen Cyanide (HCN) Gas Sensor Widely For Toxic HCN Detection In Industrial Safety Scenarios

説明
感度: 0.2±0.04 解決: 0.1 ppm
応答時間(T90): <90秒 バイアス電圧: 200~300mV
推奨される負荷抵抗: 10~100Ω 使用温度範囲: -10 ℃〜55℃
ハイライト:

HCN gas sensor for industrial safety

,

electrochemical HCN gas detector

,

toxic HCN detection sensor

 

    HCN-A1 Electrochemical Hydrogen Cyanide (HCN) Gas Sensor Widely For Toxic HCN Detection In Industrial Safety Scenarios

 

 

Description:

 

The HCN-A1 is an electrochemical gas sensor dedicated to the accurate detection of hydrogen cyanide (HCN) — a highly toxic gas. It operates based on the electrochemical reaction of HCN at the internal working electrode, where the generated current is linearly proportional to the target gas concentration (following Faraday’s Law). This sensor features a compact structure, reliable performance, and strong environmental adaptability, making it easy to integrate into portable, fixed, or handheld gas detection devices. It is designed to provide real-time concentration data for safety protection and environmental monitoring.

 

Features:

  1. High selectivity for HCN, with minimal interference from common gases like CO, H₂, and hydrocarbons.
  2. Fast response and high measurement precision, suitable for low-concentration toxic gas monitoring.
  3. Compact and lightweight design, facilitating integration into various detection equipment.
  4. Stable zero drift and long-term performance consistency, reducing maintenance frequency.
  5. Low power consumption, ideal for battery-powered portable devices.
  6. Hermetically sealed package, effectively resisting moisture and particulate interference.

Applications:

  1. Industrial Safety: Real-time HCN monitoring in chemical plants, pharmaceutical workshops, and pesticide production facilities.
  2. Petrochemical & Mining: Detection of HCN generated during coal coking, oil refining, or mineral processing.
  3. Emergency Response: Integration into portable gas detectors for rescue teams in toxic gas leakage scenarios.
  4. Confined Space Monitoring: Used in tunnels, wells, and closed workshops where HCN may accumulate.
  5. Environmental Protection: Detection of HCN emissions from waste incineration plants and chemical waste treatment sites.

 

Detection Gas Hydrogen Cyanide (HCN)
Measurement Range 0 - 50 ppm (standard range; custom ranges available)
Maximum Exposure Concentration 100 ppm (short-term, non-damaging)
Sensitivity (0.2 ± 0.04) µA/ppm
Resolution 0.1 ppm
Response Time (T90) < 90 s
Bias Voltage 200 - 300 mV (typical 250 mV)
Recommended Load Resistance 10 - 100 Ω
Repeatability < ±2% of full scale
Zero Drift (25℃) < 0.3 ppm/month
Operating Temperature Range -10℃ to 55℃
Operating Humidity Range 20% - 85% RH (non-condensing)
Storage Temperature Range -20℃ to 60℃
Pressure Range 86 - 106 kPa (standard atmosphere)
Expected Service Life 2 years (under standard operating conditions)
Package Type Metal can with pin-type leads

 

HCN-A1 Electrochemical Hydrogen Cyanide (HCN) Gas Sensor Widely For Toxic HCN Detection In Industrial Safety Scenarios 0

連絡先の詳細
ShenzhenYijiajie Electronic Co., Ltd.

コンタクトパーソン: Miss. Xu

電話番号: 86+13352990255

私達に直接お問い合わせを送信 (0 / 3000)