YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector

大画像 :  YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector

商品の詳細:
起源の場所: 英国
ブランド名: CITY
モデル番号: CL2-A1
お支払配送条件:
最小注文数量: 1
価格: 交渉可能
パッケージの詳細: パレット化
受渡し時間: 5~8日
支払条件: L/C、D/A、D/P、T/T、ウェスタンユニオン、マネーグラム
供給の能力: 1500

YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector

説明
干渉のガス: CL2ガス 反復性の間違い: 6か月で±2%
出力信号: アナログ電圧 繰り返し性: < ±2 CL2 相当
保存期間: 2年 動作温度: 0 ℃〜+50℃
使用タイプ: ポータブル機能 検知範囲: 0~20PPM
ハイライト:

chlorine gas electrochemical sensor 20ppm

,

portable chlorine gas detector sensor

,

YJJ CL2-A1 gas sensor

Product Description:

YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector

 

Features:

I. Core Parameters (Electrochemical Cl₂ Sensor)

Detected Gas: Chlorine Gas Cl₂

Measurement Range: 0 - 20 ppm (ensuring accuracy range)

Short-term Overload: Maximum tolerance 50 ppm

Sensitivity: -350 ~ -750 nA/ppm (under 10 ppm chlorine gas conditions)

Response Time T90: < 60 s (typical value < 40 s)

Resolution: < 0.02 ppm (able to detect ppb-level minor leaks)

Zero Point Current: ±0.4 ppm equivalent value

Linear Range: 0 - 5 ppm with good linearity, full range error ±1.5 ppm

Environmental Conditions

Temperature: -20℃ ~ +50℃

Humidity: 15% - 90% RH (no condensation)

Air Pressure: 80 - 120 kPa

Service Life: ≥ 24 months (original factory 24-month warranty)

Long-term Drift: Zero-point drift < 0.05 ppm/year; Sensitivity annual drift < 10%

Physical Dimensions: Φ20.2 × 16.5 mm, Weight < 6g, Standard 4-pin A-series package

Cross-Interference: SO₂ interference is small, CO, H₂, ethylene, etc. interference are extremely low, suitable for complex working conditions

II. Product Principle

Fuel cell type electrochemical sensor, chlorine gas undergoes redox reaction on the electrode surface, outputting a weak current signal, the current size is proportional to the chlorine gas concentration, the rear-end circuit converts the current into concentration values.

III. Main Applications

1) Instrument Integration (OEM preferred)

Portable chlorine gas detector, single toxic gas alarm instrument

Fixed online chlorine gas transmitter, gas monitoring probe

Industrial online monitoring module, PLC gas collection module

2) Industry Application Scenarios

Water supply / sewage treatment plants

Chlorine gas leakage monitoring in water disinfection sections, chlorination rooms, liquid chlorine steel cylinder warehouses, preventing personnel poisoning.

Chlor-alkali chemical industry, PVC synthesis production line

Pointed monitoring of minor leaks at chlorine gas pipelines, valves, reactors, liquid chlorine pumps sealing areas.

Swimming pool, swimming hall disinfection system

Monitoring of chlorine compound volatile gas concentration to ensure indoor venue occupational safety.

 fine chemicals

Tail gas and pipeline leakage detection in chlorination synthesis process workshops.

Semiconductor electronics industry

Early warning of dry etching chlorine process exhaust gas, machine gas pipeline leakage.

Environmental protection supervision, laboratory

Occupational health toxic gas detection, emergency inspection equipment.

 

Specifications:

Detected Gas CL2
Packaging 4-series
Measurement Range 0 - 20 ppm
Short-term Overload 500 ppm
Sensitivity 700 ± 250 nA/ppm

 

YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector 0