Product Description:
YJJ 161175 New Model C1 Repeated Exhalation Valve With Diaphragm
Features:
Diameter (ID, OD [mm]) / Description
Material
1 Connector OD15, ventilator side PSU
2 Tubing-PVC
3 Connectors for tubing Differential pressure measurement PSU
4 Direction index--
5 Individual serial number--
6 Connector OD22/ID15, patient sidePSU
7 Flap-PET Details Flow range 0 to 180 l/min (short term 260 l/min) Dead space
< 11 ml (functional)
Resistance
< 0.027 cmH2O/(l/min) over the complete flow range (-180 l/min to 180 l/min)
Weight
Approx. 14 g without tubes, 68 g with 188 cm tubes, 89 g with 260 cm tubes, 110 g with 330 cm tubes
Material
Complies with ISO 10993-1:2009 (biocompatibility) and Directive 2011/65/EU (RoHS).
Does not contain natural rubber latex, DEHP, or BPA.
Accuracy
For calibrated flow sensor volume-related parameters:
HAMILTON-C1/T1/MR1/C2/C3/C6 ventilators: ± 10% or ± 10 ml (whichever is greater)
HAMILTON-G5/S1 ventilators: ± 15% or ± 20 ml (whichever is greater)
Hamilton original adult disposable flow sensor is applicable to the following models:
GALILEO Galileo
RAPHAEL Raphael HAMILTON-G5
C Series
Suitable for supply of Hamilton Galileo/Galileo/Raphael/Arabella/G5/C1/C2/C3
Hamilton original C1/C2 oxygen battery 396200
C1 original battery 369108
C2 original battery
C1, T1, MR1, high-efficiency filter PN161236
C2, C3, high-efficiency filter 160216
C2 repeat exhalation valve with diaphragm 160245 New machine C1 repeat exhalation valve with diaphragm 161175 Hamilton Raphael Galileo exhalation valve 151228 GALINEO electromagnetic valve (new) 394043 RAPHAEL (Raphael) electromagnetic valve 394045 Hamilton (Raphael) original adult flow sensor 155363/281637 Hamilton (Raphael) original neonatal flow sensor 155000 Hamilton original repeatable adult flow sensor 155362
Specifications:
Temperature |
Operating: -20°C to 50°C (-4°F to 122°F) Storage: -20°C to 60°C (-4°F to 140°F) |
Operating time | 28 days or depending on hospital infection control protocols, patient secretions, and nebulization of medication |
Accessory | Tube clip, calibration adapter ID22 / OD15 |
Identification | Individual serial number |
Regulatory | Hamilton Medical has established and applies a quality management system and fulfills ISO 13485 and ISO 9001. The flow sensor has been designed to comply with: Medical Device Regulation (EU) 2017/745, EN 980, EN 1041, ISO 5356-1, ISO 10993-1, ISO 14971 |